Description

40T48 Indicator/Alarm Unit

Microprocessor-based indicator in both 48x48 (1/16 DIN) formats manufactured with SMT.

The instruments have a Lexan membrane faceplate (guaranteed to IP65) which has 3 keys, a 4 digit display, and 3 indicating LEDs for the output statuses.

The input signal can be selected from a wide range of sensors:

  • Thermocouples of type: J, K, R, S, T, B, E, N, L GOST, U, G, D, C
  • Resistance thermometers Pt100, Pt100J 2 / 3 wire
  • PTC and NTC thermistors
  • Linear inputs 0 to 60/12 to 60mV, 0 to 20/4 to 20mA, 0 to 10/2 to 10/0 to 5/1 to 5/0 to 1/0, 2 to1V

The selection is made using the faceplate keys and correct input terminals.

No external shunt or adapter is required. A digital input (24Vdc/4mA) is available for resetting, hold, flash, peak handling, or releasing the latch.

No external shunt or adapter is required. A digital input (24Vdc/5mA) is available for resetting, hold, flash, peak handling, or releasing the latch. The instruments have a maximum of 4 outputs that can be mechanical relays (5A/250V) or logic outputs 24V±10% (10Vmin / 20mA).

One output of 4 to 20mA (max. 500 Ohm) is available for transmitting the measured input signal.

The retransmission output, the digital input, and the third output are alternatives.

The options include a triac output that can directly drive resistive loads up to a maximum of 1A at 240V.

The programming of the instrument is made easy by grouping the parameters in function blocks (CFG for the alarm hysteresis, Inp for the inputs, Out for the outputs...) and by a simplified data entry menu.

The configuration can be simplified even further using the PC programming kit made up of a connection cable and a menu guide program that runs under Windows (see technical data).

A configurable personal software protection code (password protection) can be used to restrict the levels of editing and displaying the configuration parameters.

Description

  • Faceplate configurable input
  • Protected by a personal code
  • Configurable by a serial link
  • Transmitter power supply incorporated
  • Custom thermocouple linearisation is available
  • Internal linearisation for engineering units
  • Labels provided for the more common physical units
  • Sampling time and trip intervention programmable between 15 and 120msec with resolution between 2000 and 8000 steps
  • Retransmission of the measured variable signal
  • 3 trip points, completely configurable from the faceplate
  • 4 trip points are completely configurable from the keyboard
  • RS485 optically isolated serial line
  • Protocol: GEFRAN CENCAL or MODBUS RTU
  • Rapid configuration from PC with GF_eXpress package

Other SEITech Solutions products